b448e73cd2cf2ec5bdab5ed8a322c000dc5fea8f
[ Upstream commit 23c5a9488f ]
When the CAN interface is closed it the hardwre is put in power down
mode, but does not reset the error counters / state. Reset the D_CAN on
open, so the reported state and the actual state match.
According to [1], the C_CAN module doesn't have the software reset.
[1] http://www.bosch-semiconductors.com/media/ip_modules/pdf_2/c_can_fd8/users_manual_c_can_fd8_r210_1.pdf
Signed-off-by: Jeroen Hofstee <jhofstee@victronenergy.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: Sasha Levin <sashal@kernel.org>
…
Linux kernel ============ This file was moved to Documentation/admin-guide/README.rst Please notice that there are several guides for kernel developers and users. These guides can be rendered in a number of formats, like HTML and PDF. In order to build the documentation, use ``make htmldocs`` or ``make pdfdocs``. There are various text files in the Documentation/ subdirectory, several of them using the Restructured Text markup notation. See Documentation/00-INDEX for a list of what is contained in each file. Please read the Documentation/process/changes.rst file, as it contains the requirements for building and running the kernel, and information about the problems which may result by upgrading your kernel.