regulator: rk806: delete the PLDO6 enable/disable interface

The PLDO6 must be always on. if the PLDO6 is off, the PMIC
will be abnormal.

Signed-off-by: shengfei Xu <xsf@rock-chips.com>
Change-Id: I5c2cf8f0d2ba3cb08cd7538d998857d8c2db55f2
This commit is contained in:
shengfei Xu
2023-10-11 01:50:59 +00:00
committed by Xushengfei
parent 07f45d2725
commit ccaa5a7183
+15 -1
View File
@@ -942,6 +942,20 @@ static const struct regulator_ops rk806_ops_ldo = {
.set_suspend_disable = rk806_set_suspend_disable,
};
static const struct regulator_ops rk806_ops_ldo6 = {
.list_voltage = regulator_list_voltage_linear_range,
.map_voltage = regulator_map_voltage_linear_range,
.get_voltage_sel = rk806_get_voltage_sel_regmap,
.set_voltage = rk806_set_voltage,
.set_voltage_time_sel = regulator_set_voltage_time_sel,
.set_ramp_delay = rk806_set_ramp_delay,
.set_suspend_voltage = rk806_set_suspend_voltage_range,
.resume = rk806_regulator_resume,
};
#define RK806_REGULATOR(_name, _supply_name, _id, _ops,\
_n_voltages, _vr, _er, _lr, ctrl_bit)\
[_id] = {\
@@ -1033,7 +1047,7 @@ static const struct regulator_desc rk806_regulators[] = {
RK806_LDO_SEL_CNT, RK806_PLDO5_ON_VSEL,
RK806_POWER_EN5, rk806_ldo_voltage_ranges, 1),
RK806_REGULATOR("PLDO_REG6", "vcca", RK806_ID_PLDO6, rk806_ops_ldo,
RK806_REGULATOR("PLDO_REG6", "vcca", RK806_ID_PLDO6, rk806_ops_ldo6,
RK806_LDO_SEL_CNT, RK806_PLDO6_ON_VSEL,