[PATCH] asix: Fix typo for AX88772 PHY Selection
The attached patch fixes a PHY selection problem that prevents AX88772 based devices (Linksys USB200Mv2, etc) devices from working. The interface comes up and everything seems fine except the device doesn't send/receive any packets. The one-liner attached fixes this issue and makes the devices usable again. Signed-off-by: David Hollis <dhollis@davehollis.com> Signed-off-by: Chris Wright <chrisw@sous-sol.org>
This commit is contained in:
committed by
Chris Wright
parent
edfe21a29b
commit
a44a397980
@@ -920,7 +920,7 @@ static int ax88772_bind(struct usbnet *dev, struct usb_interface *intf)
|
||||
goto out2;
|
||||
|
||||
if ((ret = asix_write_cmd(dev, AX_CMD_SW_PHY_SELECT,
|
||||
0x0000, 0, 0, buf)) < 0) {
|
||||
1, 0, 0, buf)) < 0) {
|
||||
dbg("Select PHY #1 failed: %d", ret);
|
||||
goto out2;
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user