iio: chemical: pms7003: use aligned_s64 for timestamp

Follow the pattern of other drivers and use aligned_s64 for the
timestamp. This will ensure that the timestamp is correctly aligned on
all architectures.

Also move the unaligned.h header while touching this since it was the
only one not in alphabetical order.

Fixes: 13e945631c ("iio:chemical:pms7003: Fix timestamp alignment and prevent data leak.")
Signed-off-by: David Lechner <dlechner@baylibre.com>
Reviewed-by: Nuno Sá <nuno.sa@analog.com>
Link: https://patch.msgid.link/20250417-iio-more-timestamp-alignment-v1-4-eafac1e22318@baylibre.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
David Lechner
2025-04-17 11:52:36 -05:00
committed by Jonathan Cameron
parent bb49d94034
commit 6ffa698674
+3 -2
View File
@@ -5,7 +5,6 @@
* Copyright (c) Tomasz Duszynski <tduszyns@gmail.com>
*/
#include <linux/unaligned.h>
#include <linux/completion.h>
#include <linux/device.h>
#include <linux/errno.h>
@@ -19,6 +18,8 @@
#include <linux/module.h>
#include <linux/mutex.h>
#include <linux/serdev.h>
#include <linux/types.h>
#include <linux/unaligned.h>
#define PMS7003_DRIVER_NAME "pms7003"
@@ -76,7 +77,7 @@ struct pms7003_state {
/* Used to construct scan to push to the IIO buffer */
struct {
u16 data[3]; /* PM1, PM2P5, PM10 */
s64 ts;
aligned_s64 ts;
} scan;
};