[PATCH] Altix snsc: duplicate kobject fix
Fix Altix system controller (snsc) device names to include the slot number of the blade whose associated system controller is the target of the device interface. Including the slot number avoids a problem we're currently having where slots within the same enclosure are attempting to create multiple kobjects with identical names. Signed-off-by: Greg Howard <ghoward@sgi.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
89d4fdf423
commit
1f6ad287e8
+2
-1
@@ -391,7 +391,8 @@ scdrv_init(void)
|
||||
format_module_id(devnamep, geo_module(geoid),
|
||||
MODULE_FORMAT_BRIEF);
|
||||
devnamep = devname + strlen(devname);
|
||||
sprintf(devnamep, "#%d", geo_slab(geoid));
|
||||
sprintf(devnamep, "^%d#%d", geo_slot(geoid),
|
||||
geo_slab(geoid));
|
||||
|
||||
/* allocate sysctl device data */
|
||||
scd = kmalloc(sizeof (struct sysctl_data_s),
|
||||
|
||||
Reference in New Issue