5e0e4e72ca
commit54685abe66upstream. Because of hex value 0x46 used instead of decimal 46, the temp6 (PECI1) temperature is always declared visible and then displayed even if disabled in the chip Signed-off-by: Gilles Buloz <gilles.buloz@kontron.com> Link: https://lore.kernel.org/r/DU0PR10MB62526435ADBC6A85243B90E08002A@DU0PR10MB6252.EURPRD10.PROD.OUTLOOK.COM Fixes:fcdc5739dc("hwmon: (nct7802) add temperature sensor type attribute") Cc: stable@vger.kernel.org Signed-off-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>