[ Upstream commit 2cd3da4e37 ]
Intel Lunar Lake has similar integrated Thunderbolt/USB4 controller as
Intel Meteor Lake with some small differences in the host router (it has
3 DP IN adapters for instance). Add the Intel Lunar Lake PCI IDs to the
driver list of supported devices.
Tested-by: Pengfei Xu <pengfei.xu@intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Stable-dep-of: 8644b48714 ("thunderbolt: Add support for Intel Panther Lake-M/P")
Signed-off-by: Sasha Levin <sashal@kernel.org>
commit 24740385cb upstream.
When USB-C monitor is connected directly to Intel Barlow Ridge host, it
goes into "redrive" mode that basically routes the DisplayPort signals
directly from the GPU to the USB-C monitor without any tunneling needed.
However, the host router must be powered on for this to work. Aaron
reported that there are a couple of cases where this will not work with
the current code:
- Booting with USB-C monitor plugged in.
- Plugging in USB-C monitor when the host router is in sleep state
(runtime suspended).
- Plugging in USB-C device while the system is in system sleep state.
In all these cases once the host router is runtime suspended the picture
on the connected USB-C display disappears too. This is certainly not
what the user expected.
For this reason improve the redrive mode handling to keep the host
router from runtime suspending when detect that any of the above cases
is happening.
Fixes: a75e0684ef ("thunderbolt: Keep the domain powered when USB4 port is in redrive mode")
Reported-by: Aaron Rainbolt <arainbolt@kfocus.org>
Closes: https://lore.kernel.org/linux-usb/20241009220118.70bfedd0@kf-ir16/
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit 3cea8af2d1 upstream.
Currently, when configuring TMU (Time Management Unit) mode of a given
router, we take into account only its own TMU requirements ignoring
other routers in the domain. This is problematic if the router we are
configuring has lower TMU requirements than what is already configured
in the domain.
In the scenario below, we have a host router with two USB4 ports: A and
B. Port A connected to device router #1 (which supports CL states) and
existing DisplayPort tunnel, thus, the TMU mode is HiFi uni-directional.
1. Initial topology
[Host]
A/
/
[Device #1]
/
Monitor
2. Plug in device #2 (that supports CL states) to downstream port B of
the host router
[Host]
A/ B\
/ \
[Device #1] [Device #2]
/
Monitor
The TMU mode on port B and port A will be configured to LowRes which is
not what we want and will cause monitor to start flickering.
To address this we first scan the domain and search for any router
configured to HiFi uni-directional mode, and if found, configure TMU
mode of the given router to HiFi uni-directional as well.
Cc: stable@vger.kernel.org
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit d3d17e23d1 upstream.
Olliver reported that his system crashes when plugging in Thunderbolt 1
device:
BUG: kernel NULL pointer dereference, address: 0000000000000020
#PF: supervisor read access in kernel mode
#PF: error_code(0x0000) - not-present page
PGD 0 P4D 0
Oops: 0000 [#1] PREEMPT SMP NOPTI
RIP: 0010:tb_port_do_update_credits+0x1b/0x130 [thunderbolt]
Call Trace:
<TASK>
? __die+0x23/0x70
? page_fault_oops+0x171/0x4e0
? exc_page_fault+0x7f/0x180
? asm_exc_page_fault+0x26/0x30
? tb_port_do_update_credits+0x1b/0x130
? tb_switch_update_link_attributes+0x83/0xd0
tb_switch_add+0x7a2/0xfe0
tb_scan_port+0x236/0x6f0
tb_handle_hotplug+0x6db/0x900
process_one_work+0x171/0x340
worker_thread+0x27b/0x3a0
? __pfx_worker_thread+0x10/0x10
kthread+0xe5/0x120
? __pfx_kthread+0x10/0x10
ret_from_fork+0x31/0x50
? __pfx_kthread+0x10/0x10
ret_from_fork_asm+0x1b/0x30
</TASK>
This is due the fact that some Thunderbolt 1 devices only have one lane
adapter. Fix this by checking for the lane 1 before we read its credits.
Reported-by: Olliver Schinagl <oliver@schinagl.nl>
Closes: https://lore.kernel.org/linux-usb/c24c7882-6254-4e68-8f22-f3e8f65dc84f@schinagl.nl/
Fixes: 81af2952e6 ("thunderbolt: Add support for asymmetric link")
Cc: stable@vger.kernel.org
Cc: Gil Fine <gil.fine@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit f0b94c1c5c upstream.
With the current bandwidth allocation we end up reserving too much for the USB
3.x and PCIe tunnels that leads to reduced capabilities for the second
DisplayPort tunnel.
Fix this by decreasing the USB 3.x allocation to 900 Mb/s which then allows
both tunnels to get the maximum HBR2 bandwidth. This way, the reserved
bandwidth for USB 3.x and PCIe, would be 1350 Mb/s (taking weights of USB 3.x
and PCIe into account). So bandwidth allocations on a link are:
USB 3.x + PCIe tunnels => 1350 Mb/s
DisplayPort tunnel #1 => 17280 Mb/s
DisplayPort tunnel #2 => 17280 Mb/s
Total consumed bandwidth is 35910 Mb/s. So that all the above can be tunneled
on a Gen 3 link (which allows maximum of 36000 Mb/s).
Fixes: 582e70b0d3 ("thunderbolt: Change bandwidth reservations to comply USB4 v2")
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit 5391bcfa56 upstream.
We should send uevent to userspace whenever the link speed or width
changes but tb_switch_asym_enable() and tb_switch_asym_disable() set the
sw->link_width already so tb_switch_update_link_attributes() never
noticed the change.
Fix this so that we let tb_switch_update_link_attributes() update the
fields accordingly.
Fixes: 81af2952e6 ("thunderbolt: Add support for asymmetric link")
Reported-by: Pengfei Xu <pengfei.xu@intel.com>
Tested-by: Pengfei Xu <pengfei.xu@intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
[ Upstream commit b4734507ac ]
After DisplayPort tunnel setup, we add verification that the DPRX
capabilities read process completed. Otherwise, we bail out, teardown
the tunnel, and try setup another DisplayPort tunnel using next
available DP IN adapter. We do so till all DP IN adapters tried. This
way, we avoid allocating DP IN adapter and (bandwidth for it) for
unusable tunnel.
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Qin Wan <qin.wan@hp.com>
Signed-off-by: Alexandru Gagniuc <alexandru.gagniuc@hp.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
[ Upstream commit 3e36528c11 ]
USB4 v2 spec defines a Gen 4 link that can operate as an asymmetric
120/40G. When the link is asymmetric, the USB4 port on one side of the
link operates with three TX lanes and one RX lane, while the USB4 port
on the opposite side of the link operates with three RX lanes and one TX
lane. Using asymmetric link we can get much more bandwidth from one
direction and that allows us to support the new Ultra High Bit Rate
DisplayPort modes (that consume up to 77.37 Gb/s).
Add the basic logic for changing Gen 4 links to asymmetric and back
following the below rules:
1) The default threshold is 45 Gb/s (tunable by asym_threshold)
2) When DisplayPort tunnel is established, or when there is bandwidth
request through bandwidth allocation mode, the links can be
transitioned to asymmetric or symmetric (depending on the
required bandwidth).
3) Only DisplayPort bandwidth on a link, is taken into account when
deciding whether a link is transitioned to asymmetric or symmetric
4) If bandwidth on a link is >= asym_threshold transition the link to
asymmetric
5) If bandwidth on a link < asym_threshold transition the link to
symmetric (unless the bandwidth request is above currently
allocated on a tunnel).
6) If a USB4 v2 device router with symmetric link is connected,
transition all the links above it to symmetric if the bandwidth
allows.
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Co-developed-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Qin Wan <qin.wan@hp.com>
Signed-off-by: Alexandru Gagniuc <alexandru.gagniuc@hp.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
[ Upstream commit 81af2952e6 ]
USB4 v2 spec defines a Gen 4 link that can operate as an aggregated
symmetric (80/80G) or asymmetric (120/40G). When the link is asymmetric,
the USB4 port on one side of the link operates with three TX lanes and
one RX lane, while the USB4 port on the opposite side of the link
operates with three RX lanes and one TX lane.
Add support for the asymmetric link and provide functions that can be
used to transition the link to asymmetric and back.
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Co-developed-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Qin Wan <qin.wan@hp.com>
Signed-off-by: Alexandru Gagniuc <alexandru.gagniuc@hp.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
[ Upstream commit 2bfeca73e9 ]
Introduce tb_port_path_direction_downstream() to check if path from
source adapter to destination adapter is directed towards downstream.
Convert existing users to call this helper instead of open-coding.
No functional changes.
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Qin Wan <qin.wan@hp.com>
Signed-off-by: Alexandru Gagniuc <alexandru.gagniuc@hp.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
[ Upstream commit 582e70b0d3 ]
USB4 v2 Connection Manager guide (section 6.1.2.3) suggests to reserve
bandwidth in a sligthly different manner. It suggests to keep minimum of
1500 Mb/s for each path that carry a bulk traffic. Here we change the
bandwidth reservations to comply to the above for USB 3.x and PCIe
protocols over Gen 4 link, taking weights into account (that's 1500 Mb/s
for PCIe and 3000 Mb/s for USB 3.x).
For Gen 3 and below we use the existing reservation.
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Qin Wan <qin.wan@hp.com>
Signed-off-by: Alexandru Gagniuc <alexandru.gagniuc@hp.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
[ Upstream commit 8648c6465c ]
Currently we only create one DisplayPort tunnel even if there would be
more DP IN/OUT pairs available. Specifically this happens when a router
is unplugged and we check if a new DisplayPort tunnel can be created. To
cover this create tunnels as long as we find suitable DP IN/OUT pairs.
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Qin Wan <qin.wan@hp.com>
Signed-off-by: Alexandru Gagniuc <alexandru.gagniuc@hp.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit e2006140ad upstream.
I noticed that when we do discrete host router NVM upgrade and it gets
hot-removed from the PCIe side as a result of NVM firmware authentication,
if there is another host connected with enabled paths we hang in tearing
them down. This is due to fact that the Thunderbolt networking driver
also tries to cleanup the paths and ends up blocking in
tb_disconnect_xdomain_paths() waiting for the domain lock.
However, at this point we already cleaned the paths in tb_stop() so
there is really no need for tb_disconnect_xdomain_paths() to do that
anymore. Furthermore it already checks if the XDomain is unplugged and
bails out early so take advantage of that and mark the XDomain as
unplugged when we remove the parent router.
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit 985cfe501b upstream.
The margin debugfs node controls the "Enable Margin Test" field of the
lane margining operations. This field selects between either low or high
voltage margin values for voltage margin test or left or right timing
margin values for timing margin test.
According to the USB4 specification, whether or not the "Enable Margin
Test" control applies, depends on the values of the "Independent
High/Low Voltage Margin" or "Independent Left/Right Timing Margin"
capability fields for voltage and timing margin tests respectively. The
pre-existing condition enabled the debugfs node also in the case where
both low/high or left/right margins are returned, which is incorrect.
This change only enables the debugfs node in question, if the specific
required capability values are met.
Signed-off-by: Aapo Vienamo <aapo.vienamo@linux.intel.com>
Fixes: d0f1e0c2a6 ("thunderbolt: Add support for receiver lane margining")
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit 8cf9926c53 upstream.
There is no need to reset the USB4 host routers on resume because they
are reset already and this may cause problems if the link does not come
up soon enough. For this reason limit this to happen in non-USB4 host
routers only (that's Apple systems with Intel Thunderbolt controllers).
Fixes: 59a54c5f3d ("thunderbolt: Reset topology created by the boot firmware")
Cc: Sanath S <Sanath.S@amd.com>
Reviewed-by: Mario Limonciello <mario.limonciello@amd.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit c38fa07dc6 upstream.
Currently we don't configure correctly the wake events after unplug of device
router. What can happen is that the downstream ports of host router will be
configured to wake on: USB4-wake and wake-on-disconnect, but not on
wake-on-connect. This may cause the later plugged device not to wake the
domain and fail in enumeration. Fix this by clearing downstream port's "USB4
Port is Configured" bit, after unplug of a device router.
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit dcd12acaf3 upstream.
Currently we notify PM core about occurred wakes after any resume. This
is not actually needed after resume from runtime suspend. Hence, notify
PM core about occurred wakes only after resume from system sleep. Also,
if the wake occurred in USB4 router upstream port, we don't notify the
PM core about it since it is not actually needed and can cause
unexpected autowake (e.g. if /sys/power/wakeup_count is used).
While there add the missing kernel-doc for tb_switch_resume().
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit 59a54c5f3d upstream.
Boot firmware (typically BIOS) might have created tunnels of its own.
The tunnel configuration that it does might be sub-optimal. For instance
it may only support HBR2 monitors so the DisplayPort tunnels it created
may limit Linux graphics drivers. In addition there is an issue on some
AMD based systems where the BIOS does not allocate enough PCIe resources
for future topology extension. By resetting the USB4 topology the PCIe
links will be reset as well allowing Linux to re-allocate.
This aligns the behavior with Windows Connection Manager.
We already issued host router reset for USB4 v2 routers, now extend it
to USB4 v1 routers as well. For pre-USB4 (that's Apple systems) we leave
it as is and continue to discover the existing tunnels.
Suggested-by: Mario Limonciello <mario.limonciello@amd.com>
Signed-off-by: Sanath S <Sanath.S@amd.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
[ Upstream commit a75e0684ef ]
If a DiplayPort cable is directly connected to the host routers USB4
port, there is no tunnel involved but the port is in "redrive" mode
meaning that it is re-driving the DisplayPort signals from its
DisplayPort source. In this case we need to keep the domain powered on
otherwise once the domain enters D3cold the connected monitor blanks
too.
Since this happens only on Intel Barlow Ridge add a quirk that takes
runtime PM reference if we detect that the USB4 port entered redrive
mode (and release it once it exits the mode).
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
commit ec4d82f855 upstream.
The bit 23, CM TBT3 Not Supported (CNS), in ROUTER_CS_5 indicates
whether a USB4 Connection Manager is TBT3-Compatible and should be:
0b for TBT3-Compatible
1b for Not TBT3-Compatible
Fixes: b04079837b ("thunderbolt: Add initial support for USB4")
Cc: stable@vger.kernel.org
Signed-off-by: Mohammad Rahimi <rahimi.mhmmd@gmail.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit ac43c9122e upstream.
The dentry returned by debugfs_lookup() needs to be released by calling
dput() which is missing in margining_port_remove(). Fix this by calling
debugfs_lookup_and_remove() that combines both and avoids the memory leak.
Fixes: d0f1e0c2a6 ("thunderbolt: Add support for receiver lane margining")
Cc: stable@vger.kernel.org
Signed-off-by: Yaxiong Tian <tianyaxiong@kylinos.cn>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit 24d85bb3be upstream.
Fix the lane bonding procedure to follow the steps described in USB4
Connection Manager guide. Hence, set the lane bonding bit only for
downstream port. This is needed for certain ASMedia device, otherwise
lane bonding fails and the device disconnects.
Cc: stable@vger.kernel.org
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
[ Upstream commit 0c35ac1825 ]
This is not needed when firmware connection manager is run so limit this
to software connection manager.
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
Mika writes:
thunderbolt: Fix for v6.6-rc7
This includes a single commit that fixes a memory leak when DisplayPort
bandwidth allocation request is being handled by the driver.
This has been in linux-next with no reported issues.
* tag 'thunderbolt-for-v6.6-rc7' of git://git.kernel.org/pub/scm/linux/kernel/git/westeri/thunderbolt:
thunderbolt: Call tb_switch_put() once DisplayPort bandwidth request is finished
When handling DisplayPort bandwidth request tb_switch_find_by_route() is
called and it returns a router structure with reference count increased.
In order to avoid resource leak call tb_switch_put() when finished.
Fixes: 6ce3563520 ("thunderbolt: Add support for DisplayPort bandwidth allocation mode")
Cc: stable@vger.kernel.org
Signed-off-by: Gil Fine <gil.fine@linux.intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Alex reported that after rebooting the other host the peer-to-peer link
does not come up anymore. The reason for this is that the host that was
not rebooted tries to send the UUID request only 10 times according to
the USB4 Inter-Domain spec and gives up if it does not get reply. Then
when the other side is actually ready it cannot get the link established
anymore. The USB4 Inter-Domain spec requires that the discovery protocol
is restarted in that case so implement this now.
Reported-by: Alex Balcanquall <alex@alexbal.com>
Fixes: 8e1de70425 ("thunderbolt: Add support for XDomain lane bonding")
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
David reported that cppcheck found following possible copy & paste
error from tmu_mode_init():
tmu.c:385:50: style: Expression is always false because 'else if' condition matches previous condition at line 383. [multiCondition]
And indeed this is a bug. Fix it to use correct index
(TB_SWITCH_TMU_MODE_HIFI_UNI).
Reported-by: David Binderman <dcb314@hotmail.com>
Fixes: d49b4f043d ("thunderbolt: Add support for enhanced uni-directional TMU mode")
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Marek reported that when BlackMagic UltraStudio device is connected the
kernel repeatedly tries to enable lane bonding without success making
the device non-functional. It looks like the device does not have lane 1
connected at all so even though it is enabled we should not try to bond
the lanes. For this reason check that lane 1 is in fact CL0 (connected,
active) before attempting to bond the lanes.
Reported-by: Marek Šanta <teslan223@gmail.com>
Closes: https://bugzilla.kernel.org/show_bug.cgi?id=217737
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
On some systems the IOMMU blocks the first couple of driver ready
messages to the connection manager firmware as can be seen in below
excerpts:
thunderbolt 0000:06:00.0: AMD-Vi: Event logged [IO_PAGE_FAULT domain=0x0010 address=0xbb0e3400 flags=0x0020]
or
DMAR: DRHD: handling fault status reg 2
DMAR: [DMA Write] Request device [04:00.0] PASID ffffffff fault addr 69974000 [fault reason 05] PTE Write access is not set
The reason is unknown and hard to debug because we were not able to
reproduce this locally. This only happens on certain systems with Intel
Maple Ridge Thunderbolt controller. If there is a device connected when
the driver is loaded the issue does not happen either. Only when there
is nothing connected (so typically when the system is booted up).
We can work this around by sending the driver ready several times. After
a couple of retries the message goes through and the controller works
just fine. For this reason make the number of retries a parameter for
icm_request() and then for Maple Ridge (and Titan Ridge as they us the
same function but this should not matter) increase number of retries
while shortening the timeout accordingly.
Reported-by: Werner Sembach <wse@tuxedocomputers.com>
Reported-by: Konrad J Hambrick <kjhambrick@gmail.com>
Reported-by: Calvin Walton <calvin.walton@kepstin.ca>
Closes: https://bugzilla.kernel.org/show_bug.cgi?id=214259
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Mika writes:
thunderbolt: Changes for v6.6 merge window
This includes following Thunderbolt/USB4 changes for the v6.6 merge
window:
- Replace broken mailing list address in the ABI document
- Small improvements.
All these have been in linux-next with no reported issues.
* tag 'thunderbolt-for-v6.6-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/westeri/thunderbolt:
Documentation/ABI: thunderbolt: Replace 01.org in contact
thunderbolt: Check Intel vendor ID in tb_switch_get_generation()
thunderbolt: Log a warning if device links are not found
thunderbolt: Set variable tmu_params storage class specifier to static
Only Intel made Thunderbolt 1-3 devices so to avoid possible confusion
check for the Intel vendor ID before deciding the device generation.
While there move the USB4 check to happen first.
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
The software connection manager needs the device links in order to
establish the tunnels before the native protocols so log a warning if
they are not found.
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
The memory allocated in tb_queue_dp_bandwidth_request() needs to be
released once the request is handled to avoid leaking it.
Fixes: 6ce3563520 ("thunderbolt: Add support for DisplayPort bandwidth allocation mode")
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Previously, on unplug events, the TMU mode was disabled first
followed by the Time Synchronization Handshake, irrespective of
whether the tb_switch_tmu_rate_write() API was successful or not.
However, this caused a problem with Thunderbolt 3 (TBT3)
devices, as the TSPacketInterval bits were always enabled by default,
leading the host router to assume that the device router's TMU was
already enabled and preventing it from initiating the Time
Synchronization Handshake. As a result, TBT3 monitors experienced
display flickering from the second hot plug onwards.
To address this issue, we have modified the code to only disable the
Time Synchronization Handshake during TMU disable if the
tb_switch_tmu_rate_write() function is successful. This ensures that
the TBT3 devices function correctly and eliminates the display
flickering issue.
Co-developed-by: Sanath S <Sanath.S@amd.com>
Signed-off-by: Sanath S <Sanath.S@amd.com>
Signed-off-by: Sanjay R Mehta <sanju.mehta@amd.com>
Cc: stable@vger.kernel.org
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
smatch reports
drivers/thunderbolt/tmu.c:30:3: warning: symbol
'tmu_params' was not declared. Should it be static?
This variable is only used in its defining file so should be static.
Signed-off-by: Tom Rix <trix@redhat.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Intel Barlow Ridge Thunderbolt controller has 3 DP IN adapters. This
allows 3 simultaneus DisplayPort tunnels through either one or two USB4
downstream ports (in any possible configuration). Add test case for
this.
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
This adds support for the UHBR (Ultra High Bit Rate) bandwidths
introduced with DisplayPort 2.0 (and refined in 2.1). These can go up to
80 Gbit/s and their support is represent in additional bits in the DP IN
capability.
This updates the DisplayPort tunneling to support these new rates too.
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>